      NEOFOX氧含量傳感系統

       

      NEOFOX氧含量傳感系統

      NEOFOX氧含量傳感系統

      新的NeoFox相位氧含量測量系統是基于熒光的光學傳感系統,具有較高的測量穩定性,方便地校準步驟,降低您的測量成本等特性,廣泛的使用于氧含量傳感的領域中。

      NeoFox采用測量熒光的淬滅周期,相位和強度的方法來獲得氧含量的數值,特別適合于靈敏度較高或漂移較大的實驗環境,具有較高的系統穩定性。

      NeoFox只有同類相位測量系統一半的價格。

       

      Probe Specifications:
      FOXY Formulation FOSPOR Formulation HIOXY Formulation
        (general-purpose coating) (high-sensitivity for low levels of O2) (for hydrocarbon environments)
      O2% range (at 1 ATM): 0-100% 0-10% 0-20.9%
      DO range (ppm at 1 ATM): 0-40 ppm 0-4 ppm 0-8 ppm
      Temperature range: -50-+80 oC for probes -50-+80 oC for probes -50-+60 oC
      0-60 oC for patches 0-60 oC for patches NA
      O2% resolution: 0.01-0.05% .001% 0.01-0.05%
      DO resolution (at room temp): 4-20 ppb 0.4-2 ppb 4-20 ppb
      O2% accuracy: 5% of reading 5% of reading 5% of reading
      DO accuracy: 5% of reading 5% of reading 5% of reading
      Min. detectable level in gas: 0.01% - 0.05% 0.001% - 0.01% 0.01% - 0.05%
      Response time: < 1 second in gas < 1 second in gas < 1 second in gas
      ~30 seconds with overcoating in gas ~30 seconds with overcoating in gas ~45 seconds in pure water
      ~45 seconds in pure water ~45 seconds in pure water
       
      Patch Specifications:
        FOXY Formulation FOSPOR Formulation HIOXY Formulation
      02% range (at 1 ATM): 0-100% 0-20.9% 0-100%
      DO range (ppm at 1 ATM): 0-40 ppm 0-8 ppm 0-40 ppm
      Temperature range: -20 to +60 oC for patches -20 to +60 oC for patches -20 to +60 oC for patches
      02% resolution (20 sex averaging): 0.05% 0.01% 0.05%
      DO resolution (at room temp): 20 ppb 4 ppb 20 ppb
      02% accuracy: 5% of reading 5% of reading 5% of reading
      DO accuracy: 5% of reading 5% of reading 5% of reading
      Min. detectable level: 0.1% O2 0.01% O2 0.1% O2
      Min detectable level in water (at room temp): 40 ppb 4 ppb 40 ppb
      Response time: <1 second in gas <1 second in gas <1 second in gas
        ~30 seconds with overcoating in gas ~30 seconds with overcoating in gas  
        ~45 seconds in pure water ~45 seconds in pure water ~45 seconds in pure water
       
      Sterilization Guide:
        FOXY Formulation FOSPOR Formulation HIOXY Formulation
      Form factor: Probes/Patches Probes/Patches Probes
      Autoclavable: No No Yes
      Calibration:     Single point reset required after sterilization

       